8 resultados para Reduces Infarct Size

em QUB Research Portal - Research Directory and Institutional Repository for Queen's University Belfast


Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have previously demonstrated that remote ischemic preconditioning (IPC) by instigation of three cycles of 10-min occlusion/reperfusion in a hindlimb of the pig elicits an early phase of infarct protection in local and distant skeletal muscles subjected to 4 h of ischemia immediately after remote IPC. The aim of this project was to test our hypothesis that hindlimb remote IPC also induces a late phase of infarct protection in skeletal muscle and that K(ATP) channels play a pivotal role in the trigger and mediator mechanisms. We observed that pig bilateral latissimus dorsi (LD) muscle flaps sustained 46 +/- 2% infarction when subjected to 4 h of ischemia/48 h of reperfusion. The late phase of infarct protection appeared at 24 h and lasted up to 72 h after hindlimb remote IPC. The LD muscle infarction was reduced to 28 +/- 3, 26 +/- 1, 23 +/- 2, 24 +/- 2 and 24 +/- 4% at 24, 28, 36, 48 and 72 h after remote IPC, respectively (P <0.05; n = 8). In subsequent studies, hindlimb remote IPC or intravenous injection of the sarcolemmal K(ATP) (sK(ATP)) channel opener P-1075 (2 microg/kg) at 24 h before 4 h of sustained ischemia (i.e., late preconditioning) reduced muscle infarction from 43 +/- 4% (ischemic control) to 24 +/- 2 and 19 +/- 3%, respectively (P <0.05, n = 8). Intravenous injection of the sK(ATP) channel inhibitor HMR 1098 (6 mg/kg) or the nonspecific K(ATP) channel inhibitor glibenclamide (Glib; 1 mg/kg) at 10 min before remote IPC completely blocked the infarct- protective effect of remote IPC in LD muscle flaps subjected to 4 h of sustained ischemia at 24 h after remote IPC. Intravenous bolus injection of the mitochondrial K(ATP) (mK(ATP)) channel inhibitor 5-hydroxydecanoate (5-HD; 5 mg/kg) immediately before remote IPC and 30-min intravenous infusion of 5-HD (5 mg/kg) during remote IPC did not affect the infarct-protective effect of remote IPC in LD muscle flaps. However, intravenous Glib or 5-HD, but not HMR 1098, given 24 h after remote IPC completely blocked the late infarct-protective effect of remote IPC in LD muscle flaps. None of these drug treatments affected the infarct size of control LD muscle flaps. The late phase of infarct protection was associated with a higher (P <0.05) muscle content of ATP at the end of 4 h of ischemia and 1.5 h of reperfusion and a lower (P <0.05) neutrophilic activity at the end of 1.5 h of reperfusion compared with the time-matched control. In conclusion, these findings support our hypothesis that hindlimb remote IPC induces an uninterrupted long (48 h) late phase of infarct protection, and sK(ATP) and mK(ATP) channels play a central role in the trigger and mediator mechanism, respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oxidative stress plays an important role in the development of cardiac remodeling after myocardial infarction (MI), but the sources of oxidative stress remain unclear. We investigated the role of Nox2-containing reduced nicotinamide-adenine dinucleotide phosphate oxidase in the development of cardiac remodeling after MI. Adult Nox2(-/-) and matched wild-type (WT) mice were subjected to coronary artery ligation and studied 4 weeks later. Infarct size after MI was similar in Nox2(-/-) and WT mice. Nox2(-/-) mice exhibited significantly less left ventricular (LV) cavity dilatation and dysfunction after MI than WT mice (eg, echocardiographic LV end-diastolic volume: 75.7+/-5.8 versus 112.4+/-12.3 microL; ejection fraction: 41.6+/-3.7 versus 32.9+/-3.2%; both P

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The laboratory mouse is a powerful tool in cardiovascular research. In this report, we describe a method for a reproducible mouse myocardial infarction model that would allow subsequent comparative and quantitative studies on molecular and pathophysiological variables. Methods: (A) The distribution of the major coronary arteries including the septal artery in the left ventricle of the C57BL/6J mice (n=20) was mapped by perfusion of latex dye or fluorescent beads through the aorta. (B) The territory of myocardial infarction after the ligation of the most proximal aspect of the left anterior descending (LAD) coronary artery was quantified. (C) The consistency in the histological changes parallel to the infarction at different time points was analyzed. Results: (A) The coronary artery tree of the mouse is different from human and, particularly, in regard to the blood supply of the septum. (B) Contrary to previous belief, the septal coronary artery in the mouse is variable in origin. (C) A constant ligation of the LAD immediately below the left auricular level ensures a statistically significant reproducible infarct size. (D) The ischemic changes can be monitored at a histological level in a way similar to what is described in the human. Conclusion: We illustrate a method for maximal reproducibility of experimental acute myocardial infarction in the mouse model, due to a consistent loss of perfusion in the lower half of the left ventricle. This will allow the study of molecular and physiological variables in a controlled and quantifiable experimental model environment. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new method is proposed which reduces the size of the memory needed to implement multirate vector quantizers. Investigations have shown that the performance of the coders implemented using this approach is comparable to that obtained from standard systems. The proposed method can therefore be used to reduce the hardware required to implement real-time speech coders.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Glucagon-like peptide-1 (GLP-1) therapies are routinely used for glycaemic control in diabetes and their emerging cardiovascular actions have been a major recent research focus. In addition to GLP-1 receptor activation, the metabolically-inactive breakdown product, GLP-1(9-36)amide, also appears to exert notable cardiovascular effects, including protection against acute cardiac ischaemia. Here, we specifically studied the influence of GLP-1(9-36)amide on chronic post-myocardial infarction (MI) remodelling, which is a major driver of heart failure progression.

METHODS: Adult female C57BL/6 J mice were subjected to permanent coronary artery ligation or sham surgery prior to continuous infusion with GLP-1(9-36)amide or vehicle control for 4 weeks.

RESULTS: Infarct size was similar between groups with no effect of GLP-1(9-36)amide on MI-induced cardiac hypertrophy, although modest reduction of in vitro phenylephrine-induced H9c2 cardiomyoblast hypertrophy was observed. Whilst echocardiographic systolic dysfunction post-MI remained unchanged, diastolic dysfunction (decreased mitral valve E/A ratio, increased E wave deceleration rate) was improved by GLP-1(9-36)amide treatment. This was associated with modulation of genes related to extracellular matrix turnover (MMP-2, MMP-9, TIMP-2), although interstitial fibrosis and pro-fibrotic gene expression were unaltered by GLP-1(9-36)amide. Cardiac macrophage infiltration was also reduced by GLP-1(9-36)amide together with pro-inflammatory cytokine expression (IL-1β, IL-6, MCP-1), whilst in vitro studies using RAW264.7 macrophages revealed global potentiation of basal pro-inflammatory and tissue protective cytokines (e.g. IL-1β, TNF-α, IL-10, Fizz1) in the presence of GLP-1(9-36)amide versus exendin-4.

CONCLUSIONS: These data suggest that GLP-1(9-36)amide confers selective protection against post-MI remodelling via preferential preservation of diastolic function, most likely due to modulation of infiltrating macrophages, indicating that this often overlooked GLP-1 breakdown product may exert significant actions in this setting which should be considered in the context of GLP-1 therapy in patients with cardiovascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contestants can either assess their own resource-holding potential relative to their opponent (mutual assessment) or rely solely on the assessment of their own fighting ability (self-assessment). To discriminate between these possibilities, we staged dyadic territorial contests between 'size-matched' male swordtails. These contests consist of a combination of ritualized displays and direct fighting. Although size differences were small, winners were larger than losers and smaller fish tended to be winners only when the size difference was negligible. Body size, however, did not influence contest duration and there was no increase in contest duration with mean body size; thus, there is no support for self-assessment in these animals. We also examined the effects of the sword, which comprises a sexually selected extension used in female choice that reduces swimming efficiency but increases acceleration. The length of the sword (adjusted for body size) did not differ between winners and losers; however, losers conceded earlier if the opponent had a large sword for its body size but this decision was independent of the loser's own sword length. Losers thus assessed the swords of winners, which precludes self-assessment; however, because winners appeared not to assess the swords of losers, this does not fully support the idea of mutual assessment. (c) 2008 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the effect of intestinal manipulation and mesenteric traction on gastro-intestinal function and postoperative recovery in patients undergoing abdominal aortic aneurysm (AAA) repair. Methods: Thirty-five patients undergoing AAA repair were randomised into 3 groups. Group I (n = II) had repair via retroperitoneal approach while Group II (n = 12) and Group III (n = 12) were repaired via transperitoneal approach with bowel packed within the peritoneal cavity or exteriorised in a bowel bag respectively. Gastric emptying was measured pre-operatively (day 0), day 1 and day 3 using paracetamol absorption test (PAT) and area under curve (P-AUC) was calculated. Intestinal permeability was measured using the Lactulose-Mannitol test. Results: Aneurysm size, operation time and PAT (on day 0 and day 3) were similar in the three groups. On day 1, the P-AUC was significantly higher in Group I, when compared with Group II and Group III (P = .02). Resumption of diet was also significantly earlier in Group I as compared to Group II and Group III. The intestinal permeability was significantly increased in Group II and Group III at day 1 when compared with day 0, with no significant increase in Group I. Retroperitoneal repair was also associated with significantly shorter intensive care unit (P = .04) and hospital stay (P = .047), when compared with the combined transperitoneal repair group (Group II and III). Conclusion: Retroperitoneal AAA repair minimises intestinal dysfunction and may lead to quicker patient recovery when compared to transperitoneal repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The eluent droplet size defines the number of sampling compartments in a continuously operated annular electrochromatograph and therefore influences separation efficiency. In this work, an assembly of two capillaries, a feeding capillary on the top and a receiving capillary placed under it, has been investigated to control droplet size. The receiving capillary prevents the liquid droplet formation beyond a critical size, which reduces the volume of sampling compartment as compared with the case of the electrolyte flow driven solely by gravity. With a receiving capillary, the electrolyte droplet size was reduced from 1.5 to 0.46 mm. Further decrease of droplet size was not possible due to a so-called droplet jump upwards effect which has been observed on a hydrophilic glass surface with water. A typical electrolyte used in CAEC has high methanol content. In an attempt to improve the methanol-repellent properties of the glass surface, two approaches have been implemented: (i) self-assembled chemisorbed monolayers of an alkylsiloxane and (ii) fabrication of a nano-pin film. The methanol-repellent surface of the feeding capillary suppressed the droplet jump upwards effect. The surface remained methanol repellent in different solutions with lower polarity than that of water.